Sequential Identity Verification · Stage 1
Same stimulus. Different brains.
Assume we can measure a brain’s response accurately in real time. Would two responses from the same person, on different days, be more alike than responses from different people?
- Person A
- First visit
- Person A
- Later visit
- Person B
- Later visit
Acquisition metadata · what has actually been checked
An EEG file and a cue log are not yet one timeline.
We inspected one acquisition header and compared its declared layout with the retained cue sidecar. The two counts do not support assuming that each cue-log row matches one sample position.
Header declares
- Serialized streams
- 67
- Declared records
- 430 × 1 second
- Nominal positions per 1,000-slot channel
- 430,000
66 channels declare 1,000 slots per record; one further stream is an annotation channel. These are not all brain-signal channels: the layout also includes a marker candidate labelled Trig.
Header declarations—not observed samples or verified physical timing.
Sidecar contains
430,200 rows
This is the actual row count of the retained cue log. Its rows belong to a separate file; a row count does not establish a shared sample clock.
Cue labels and numeric times still need an evidenced relationship to the acquisition stream.
Not yet matched
No one-to-one mapping established.
The counts differ. That does not show a 200-sample delay, a trim point or which stream started first.
- Sample-to-cue relationship
- Marker and annotation mapping
- Physical stimulus onset
No rows were silently trimmed and no offset was selected.
No physiological samples from this collection have been analyzed. Header consistency does not establish response stability, identity, liveness or security.
What the header-only check establishes—and leaves open
One bounded header-only acquisition returned 17,457 bytes of application response bodies. No declared physiological sample records were requested. Raw patient, record and recording-start identifiers were not persisted.
The reviewed reader accepted the header declarations; an independent check verified retained sanitized metadata and layout arithmetic. That was not a second independent decode of the discarded raw header. The declared sample layout matches the retained ZIP member size, but whole-entry CRC, whole-archive checksum and source authenticity remain unverified. Stable object identity across responses and final redirect destination were not established.
The annotation stream declares 10 slots per record, not 10 observed events or a 10 Hz brain signal. Trig calibration limits are not observed trigger values. Neither sampled markers nor annotation onsets were analyzed, and the sidecar clock’s origin and relationship remain open. No physiological alignment, converter fidelity or physical-onset validation follows.
Frozen Eye-BCI v1 source · The record advertises a newer version that has not been checked here.
Stage 1 remains open. Response stability, added value from change history, liveness, replay or injected-signal resistance, and account control are separate research questions. These metadata checks establish none of them.
What small studies found
One checkerboard study matched 19 of 20 recordings to the correct participant in a group of 10 people, each tested twice. Other work found that some response features were less stable across visits. A difference in a small group leaves open whether it is reliable across people, days and conditions.
What would count as evidence?
Compare responses from independent visits, measure how much learning, fatigue and other changes affect them, and check whether the differences are specific to the stimulus. The lab has defined the initial comparison and has yet to collect measurements.
Could an existing dataset help?
A published visual-flicker study reports 30 people recorded on two different days. Each person saw the three frequency bands in the same order on both days, although trials within each band were randomized. Repeating the band order could make sessions look more alike. The study does not establish stability across weeks. We still need to verify the deposited files and reuse terms before analysis.
Primary dataset description ↗A second candidate, Eye-BCI’s frozen v1 archive, contains 63 sessions across 31 participants; 17 participants have at least two sessions. These are candidate records, not qualified longitudinal comparisons. Earlier metadata checks found conflicting labels. We have now checked one session’s complete synchronization metadata: 40 ordered cue pairings agree with its experiment log, with 10 cues at each of 10, 11, 12 and 13 Hz. That observed schema conflicts with v1’s advertised 48 trials and different frequency set; the record advertises a newer version that we have not checked. Generic “Stimulus” labels and frequency-bearing phases refer to different intervals. This resolves one label-mapping ambiguity, not physical flicker timing or EEG alignment. Other sessions, attention and recording confounds still need checks. No physiological signals from this collection have been analyzed, and no response stability or distinctiveness result follows.